hirly

Apply with hirly

Senior OT / SCADA Integration & Commissioning Lead

Ferrovial · London

Upload your resume to see how well you match this job — free, in seconds, no account needed.

Your resume is used only to score it against this job. If you don't create an account, it is deleted within 24 hours.

Join Ferrovial: Where Innovation Meets Opportunity Are you ready to elevate your career with a global leader in infrastructure solving complex problems and generating a positive outcome on people’s lives? At Ferrovial , we are not just a company; we are a community of innovators and trailblazers. Listed on three major stock markets: Nasdaq (US), Euronext Amsterdam (Netherlands) and IBEX 35 (Spain), we are also member of the Dow Jones Sustainability Index and FTSE4Good. We operate in more than 15 countries and have a workforce of over 24,000 professionals worldwide. Ferrovial’s activity is carried out through our business units, including Highways, Airports, Construction, and Energy. Why Ferrovial?

  • Global presence, local impact : Be part of a company that is shaping the future of infrastructure worldwide, with challenging roles and projects that make a real difference.
  • Collaborative excellence : Work alongside talented professionals in a collaborative environment where your ideas and contributions are valued.
  • Inclusive Culture: Thrive in an innovative and respectful workplace that values every voice, celebrates what makes us unique and turns differences into innovation.
  • Career growth : Benefit from global and cross-business unit mobility, with development processes designed to ensure your professional growth.
  • Compelling benefits and employee wellbeing : Enjoy a comprehensive benefits package that rewards your hard work and dedication and take advantage of initiatives designed to support your physical and psychological health.
  • Productivity tools : Utilize cutting-edge tools like Microsoft Copilot to enhance your productivity and efficiency. Job Description: Senior OT / SCADA Integration & Commissioning Lead (Industrial Automation & Infrastructure Projects) 1.

Role Purpose

We are seeking a Senior OT / SCADA Integration & Commissioning Lead to support the delivery of complex industrial and infrastructure projects, with a focus on system integration, commissioning and technical coordination in field environments. The role is designed for a senior technical professional evolved into coordination, capable of operating between:

  • hands-on SCADA / PLC work
  • system-level integration
  • coordination of EPC contractors, vendors and operations This is not a pure Project Manager role, but a technical delivery and integration role. Location: London 2.

Role Context

The position sits within projects characterised by:

  • multi-vendor SCADA environments
  • complex OT system integration
  • commissioning-intensive phases
  • interaction with EPCs, OEMs and plant operators Key challenge: ensuring systems are not only installed, but fully integrated and operational in real conditions Based: London based 3.

Key Responsibilities

3.1 Commissioning & Integration

  • Lead and execute SCADA and control systems commissioning activities
  • Validate integration between:
  • PLC systems
  • SCADA platforms
  • third-party/OEM systems
  • Ensure correct behaviour of:
  • signals
  • commands vs feedback
  • system states 3.2 Industrial Networks & Communications ( Core Capability )
  • Lead and support the configuration, validation and troubleshooting of industrial communication networks as a core part of system integration and commissioning. Network Configuration & Infrastructure
  • Work hands-on with industrial network infrastructure, including:
  • configuration of managed industrial switches
  • IP addressing aligned with system architecture
  • VLAN configuration and traffic segmentation
  • basic routing concepts (subnets, gateways, inter-network communication)
  • Support and validate network topologies:
  • star / ring / redundant architectures
  • distributed I/O networks
  • separation between control, SCADA and external systems Industrial Protocols & Data Flow
  • Ensure correct configuration and operation of: Profinet, Modbus TCP,

Opc Ua

  • Validate end-to-end data flow across: field devices, PLCs, SCADA systems
  • Identify and resolve:
  • data inconsistencies or stale values
  • intermittent communication
  • addressing/configuration mismatch
  • protocol-level issues Network Diagnostics & Troubleshooting
  • Diagnose issues such as:
  • connectivity failures
  • latency / instability
  • physical layer issues (cabling, ports, redundancy switching)
  • switch misconfiguration
  • Apply structured troubleshooting:
  • trace signals (field → PLC → network → SCADA)
  • isolate root cause (logic vs network vs configuration)
  • validate real vs displayed system state Integration with System Behaviour
  • Ensure network configuration supports:
  • reliable command execution
  • feedback consistency
  • real-time performance
  • Detect scenarios where:
  • systems appear functional but are degraded
  • SCADA does not reflect real system state Coordination with OT & Infrastructure Teams
  • Interface with:
  • network / IT / OT security
  • vendors / integrators
  • Align:
  • network configuration
  • system architecture
  • commissioning requirements Operational Reliability & Readiness
  • Validate that networks are: stable, properly structured, aligned with system criticality
  • Ensure readiness for: FAT / SAT, commissioning, handover System Coherence & Cross-Layer Ownership (PLC – Network – SCADA)
  • Own and ensure end-to-end coherence of system behaviour across: field devices, PLC logic, industrial network, SCADA systems Single Source of Truth
  • Ensure full alignment between: PLC states, transmitted data, SCADA representation
  • Resolve discrepancies between: commanded vs actual state, logic vs visualisation, real system vs operator perception End-to-End Traceability
  • Validate traceability of signals: field → PLC → network → SCADA
  • Diagnose issues by: tracing signal origin, analysing transformations, validating final behaviour False State Detection
  • Identify situations where:
  • SCADA shows operation but system is not functioning
  • feedback does not reflect real status
  • communication creates false truths
  • Ensure system avoids: misleading status, silent failures, undetected degradation Cross-Domain Integration
  • Ensure that: PLC logic, communications, SCADA operate as a single coherent system. Resolution Ownership
  • Take responsibility for resolving issues across: PLC, network, SCADA avoiding gaps between disciplines or vendors Operational Trust
  • Ensure system behaviour is: predictable, verifiable, aligned with reality 3.4 Technical Coordination
  • Act as interface between: EPC contractors, SCADA vendors, engineering teams, operations
  • Align implementation with operational needs
  • Coordinate during: startup, shutdown, commissioning 3.5 System Validation & Troubleshooting
  • Identify and resolve integration issues across: communications, SCADA-PLC interaction, instrumentation
  • Validate full system behaviour under real conditions SCADA & OT Systems
  • Support SCADA platforms: PcVue, PCS7, WinCC / AVEVA
  • Ensure: proper alarms, monitoring, data coherence 3.7 Project Delivery Support
  • Support FAT/SAT
  • Contribute to delivery readiness
  • Mitigate risks related to: Integration, sequencing, dependencies 4.

Required Profile

Experience

  • Strong industrial automation / SCADA experience
  • Strong experience in: commissioning, system integration, field environments
  • Experience in: infrastructure / energy / industrial projects, EPC environments
  • Real commissioning experience
  • System-level troubleshooting capability
  • Ability to detect cross-layer inconsistencies (PLC–Network–SCADA) Technical Background SCADA: PcVue, PCS7, WinCC, AVEVA PLC: Siemens (TIA Portal preferred), Schneider, Codesys Communications & Networks
  • Profinet
  • Modbus •

Opc Ua

  • industrial networks
  • Practical experience in: switch configuration, network troubleshooting in field Systems & Delivery
  • commissioning
  • integration
  • coordination Additional
  • PV plants / energy
  • industrial retrofit
  • infrastructure systems *Please note that this job description does not represent a comprehensive list of activities and employees may